According to the Regulation of Thermal Installations in Buildings (RITE) , approved by Royal Decree 1027/2007, of July 20, indicates that the relative humidity in indoor conditions for people with sedentary metabolic activity must be set between 40% and 60% , depending on the season of the year.

Offices are spaces where many people spend most of their time. Maintaining humidity levels in work spaces at an optimal range is essential to take care of the comfort and health of workers. To achieve this, the ideal relative humidity level in offices should be maintained at 50% throughout the year, especially in winter, when it drops the most due to forced air renewal.

The RITE regulations allow maintaining the relative humidity between 40% and 60% HR; being compatible levels for optimal user comfort , increasing the concentration and efficiency of employees during the workday. Other benefits obtained by keeping the RH at 50% are:

  1. Reduction of the electrostatic charge of the indoor air.
  2. Reduction in absenteeism due to health problems caused by dry air, eye irritation, skin problems, respiratory diseases, increased stress and occupational diseases such as Semicircular Lipoatrophy.


Electronic equipment such as printers, copiers, computers, and phones are also affected by electrostatic buildup .

Overall, humidity control can improve equipment performance and infrastructure maintenance in offices while keeping workers happy, motivated and comfortable.

Benefits of Neptronic Humidification Systems

  • Improved indoor air quality, health and comfort
  • Helps reduce absenteeism
  • Lower heating costs with high temperature perception
  • Improvement of the operation of electronic equipment
  • Can be monitored and controlled with our range of accessories

Discover our selection of Neptronic humidifiers for offices

Neptronic humidification systems for humidity control in offices

Neptronic SKE4 – Resistance steam humidifier

1. Capacities from 6 to 300 lb/hr (2.7 to 136 kg/hr)
2. Stainless steel evaporation chamber quickly without tools
3. Patent pending water level detection system using 2 sensor technologies
4. Available with BACnet MS/TP or Modbus communication interface
5. Optional Ethernet module for BACnet IP or Modbus IP, and web services
6. Independent programming system for unit operation and drain cycle


Click here to discover the SKE4 range

Neptronic humidification systems for humidity control in offices

Neptronic SKG4 – Gas Steam Humidifier

1. Steam capacity from 110 to 810 lb/h (50 to 370 kg/h)
2. Functions with tap water, RO or DI
3. Combustion efficiency: 83% to 87%
4. Simple maintenance: clean and reinstall in
5. matter of minutes
6. Waste water drained below 140°F (60°C)
7. Smallest footprint in the industry
8. Advanced controller with multiple connectivity options
9. Self-adjusting burner for altitude compensation


Request more information about the SKS4 range here

Neptronic humidification systems for humidity control in offices

Neptronic SKR – Resistance steam humidifier

1. Steam capacity 4.5 to 12 lb/hr (2 to 5.4 kg/hr)
2. Cleanable stainless steel permanent evaporation chamber
3. Patented siphon drain requires no drain valve or external faucet
4. Environmentally friendly: no plastic cylinders to replace
5. On/Off operation, modulation optional
6. Warm drain water below 140°F (60°C)
7. Self-cleaning heating elements


Click here to learn about the SKR model

Neptronic humidification systems for humidity control in offices

Neptronic SKS – Steam Humidifier

1. Capacities from 17 to 1250 lbs/hr (8 to 570 kg/hr) of steam
2. Stainless steel heat exchangers (for raw steam)
3. Comprehensive scale management system
4. Ease of maintenance – clean and reinstall in minutes
5. Patent pending water level detection system using 2 sensor technologies
6. Use domestic, RO or DI water
7. Available with BACnet MS/TP or Modbus communication
8. Optional Ethernet module for BACnet IP or Modbus IP and web services
9. Warm drain water below 140°F (60°C)


Find out more about the SKS4 range